dmx512 LED lifting football lamp

This product is intact before delivery.In order to keep the product in good condition and ensure safe operation, users should follow the safety precautions and warnings in this manual.

Important: Damage caused by not following this manual is not covered by the warranty.The supplier shall not be responsible for the product problems caused thereby.

If the product has ever been exposed to extreme unstable temperature environment (such as after transportation), please do not connect the power supply of the product immediately, because the water droplets generated due to temperature changes may damage the product.Please use it after the product returns to normal temperature.

This product can be used in the voltage range of 100-240V. It is used indoors.Please ensure that the ground voltage used is not higher than the range that the product can bear!!The power plug must be plugged into a Class I socket with good protection.The green or teal conductor must be grounded

DMX512 signal connection

This lamp uses DMX512 signal control mode, and the control signals of each lamp are in parallel relationship. When connecting multiple lamp signals, it is better to use a double core shielded cable. When connecting, each lamp is connected through the DMX signal jack (XLR seat) INPUT and OUTPUT on the lamp. The three core XLR plug terminals of the signal line connecting the lamp must correspond to each other. When connecting the lamp signal,It is recommended to use DMX signal amplifier to avoid damaging control signal due to electric noise.

Calculation method of lamp starting address code:

The starting address code of the current lamp is equal to (the starting address code of the previous lamp)+(the number of channels of the lamp) Description:

1: The starting address code value of the first lamp A001

2: The number of basic channels of the controller shall be greater than or equal to the total number of channels used by the lamp

3: Note: When using any controller, each lamp must have its own starting address code. If the starting address code of the first lamp is set as A001, the number of channels of the lamp is 10CH;Then the starting address code of the second lamp is set to A011;The starting address code of the third lamp is set to A021;By analogy, (this setting mode also needs to be determined according to different consoles).

Installation instructions of lamps:

This lamp only supports hanging. When hanging, pay attention to the installation method (do not tilt). Fixed installation of the lamp: before positioning the lamp, ensure the stability of the installation site. When hanging installation, ensure that the lamp does not fall off the support, and use safety ropes to wear the support and lamp handle for auxiliary hanging;To ensure safety and prevent lamps from falling and sliding. During installation and commissioning of lamps, pedestrians are not allowed to pass below. Regularly check whether the safety rope is worn and whether the hook screw is loose. The manufacturer will not bear any responsibility for all consequences caused by lamps falling due to unstable hanging installation

 Menu description

Change the channel value.Press OK again to save the modified values and exit editing. Press Exit to exit editing without saving the modified values.

 

  • Schematic part:

 

  1. Function keys
  2. Keying
  3. Minus key
  4. Confirm key
  5. LED display window

A    B    C   D
Operating instructions: Press function key A to cycle the menu function effect. The first two digits of the nixie tube represent the current function (refer to the menu).The last two digits represent the address code, or the speed, parameter of the function.Press B or C to modify the parameter value.Press D to confirm.

LED display window function comparison table (press to select all functions and then press D to confirm)

S/NdisplayFunction description
1AddrAddress code, (001-512)

B. C key plus or minus address code value

2ShouOperation mode selection
3Chnd10CH
4LEDON,OFF;LED no operation automatic on/off selection
5DispYES, NO reverse display
6UerVersion No
7FAETYES, NO Restore factory settings
  1. DMX512 10 Channel Description
S/Nfunctionexplain
Channel 1Lifting0-255
Channel 2Lifting speed0-255
Channel 3Total dimming0-255
Channel 4Stroboscopic0-10, 11-255
Channel 5gules0-255
Channel 6green0-255
Channel 7blue0-255
Channel 8white0-255
Channel 9Gold0-255
Channel 10reset0-240 invalid, 241-255 delayed for 3 seconds to reset

 

  • Description
  • Global Tab

Technical parameters:

Voltage: AC100~240V 50/60HZ

Power: 150W

Lifting stroke: 6 meters

Maximum load-bearing: ≤2.5KG

Speed: ≤0.6m/s

Anti-fall mode: physical braking, electronic protection.

Lamp beads: 8 *15w four-in-one lamp beads, 8 *15w gold light beads

Control mode: DMX512, self-propelled, master-slave.

CHANNEL: 10CH

Dimming: 0~100% linear dimming

Operating temperature: indoor -20 degrees ~ 50 degrees

Strobe frequency: 1~30HZ

Appearance: Metal, Flame Retardant Plastic Black

Connection method: DMX512 input and output / power input and output.

IP rating: IP20

Lift size: 26*13*29cm

Lift weight: 7.5KG

Ball size: 20CM

BALL WEIGHT: 1.2KG

PACK OF TWO BALL SIZES: 51*27*28 GALL WEIGHT: 3.85KG

Lift one pack of two sizes: 39*33*49 Gross weight: 16KG

Application:

1.Complete control board with DMX in/out.
2.Newest inductor with shielding function,show more smooth dimmer.
3.Electric motor driver has stronger power to moving winch
4.More thichness motor for Kinetic light ,will move more quickly and facile.
5.Lift cable smaller and firm from Japan.
6.Fall protection, Newest and safe design which is add electromagnetic valve.
7.Can be customized